UMX-TPS-TX100 series
User’s Manual
Section 7.
LW2 Programmer’s reference
Page 73 / 127
7.4.3. Query the RS-232 port settings
Description:
The RS-232 port settings can be queried as follows:
Format
Example1
Command {RS232_LOCAL_FORMAT=?}
→ {rs232_local_format=?}
Response (RS232_LOCAL_FORMAT=
<baud>;<data bits>; <parity>;
<stop bits>)CrLf
← (RS232_LOCAL_FORMAT=57600;
8;N;1)CrLf
Legend:
<baud>:
Baud rate which can be 4800, 7200, 9600, 14400, 19200,
38400, 57600, 115200
<data bits>: 8 or 9
<parity>:
N (none), O (odd), E (even)
<stop bits>: 1, 1.5, 2
Explanation1:
Current RS-232 settings on local port: Baud rate is 57600, 8 data bits, no
parity, 1 stop bit.
Format
Example2
Command {RS232_LINK_FORMAT=?}
→ {rs232_link_format=?}
Response (RS232_LINK_FORMAT=
<baud>;<data bits>;
<parity>; <stop bits>)CrLf
← (RS232_LINK_FORMAT=9600;
8;N;1)CrLf
Legend:
Same as above.
Explanation2:
Current RS-232 settings on link port: Baud rate is 9600, 8 data bits, no
parity, 1 stop bit.
7.4.4. Change RS-232 port settings
Description:
The RS-232 port settings can be set as follows:
Format
Example1
Command {RS232_LOCAL_FORMAT=
<baud>;<data bits>;
<parity>; <stop bits>}
→ {rs232_local_format=57600;9;N;1}
Response (RS232_LOCAL_FORMAT=
<baud>;<data bits>;
<parity>; <stop bits>)CrLf
← (RS232_LOCAL_FORMAT=57600;
9;N;1)CrLf
Legend:
See section
on page
Explanation1:
RS-232 settings on the local port have been set as follows: Baud rate is
57600, 9 data bits, no parity, 1 stop bit.
Format
Example2
Command {RS232_LINK_FORMAT=
<baud>;<data bits>;
<parity>; <stop bits>}
→ {rs232_link_format=9600;9;N;1}
Response (RS232_LINK_FORMAT=
<baud>;<data bits>;
<parity>; <stop bits>)CrLf
← (RS232_LINK_FORMAT=9600;
9;N;1)CrLf
Legend:
See section
on page
Explanation2:
RS-232 settings on the link port have been set as follows: Baud rate is
9600, 9 data bits, no parity, 1 stop bit.
Info: If the device is connected to an MX-TPS-IB, the port settings (Baud rate, databits, stop bits,
parity) are ignored, since the followings pre-defined values are valid: 115200 8N1.