Page 98 / 127
Section 8.
LW3 Programmers’ reference
8.7.3. Databit setting
Command format:
SET●
/
SYS/MB/RS232/{Local|Link}.DataBits={8|9}
Response format:
pw●/SYS/MB/RS232/{Local|Link}.DataBits={8|9}
Example:
> SET●/SYS/MB/RS232/Local.DataBits=8
< pw●/SYS/MB/RS232/Local.DataBits=8
Parameters:
.DataBits
Data bits value
8
8
9
9
8.7.4. Stopbits setting
Command format:
SET●/SYS/MB/RS232/{Local|Link}.StopBits={0|1|2}
Response format:
pw●/SYS/MB/RS232/{Local|Link}.StopBits={0|1|2}
Example:
> SET●/SYS/MB/RS232/Local.StopBits=0
< pw●/SYS/MB/RS232/Local.StopBits=0
Parameters:
.StopBits
Stopbit value
0
1
1
1,5
2
2
8.7.5. Parity setting
Command format:
SET●/SYS/MB/RS232/{Local|Link}.Parity={0|1|2}
Response format:
pw●/SYS/MB/RS232/{Local|Link}.Parity={0|1|2}
Example:
> SET●/SYS/MB/RS232/Local.Parity=0
< pw●/SYS/MB/RS232/Local.Parity=0
Parameters:
.Parity
Parity setting
0
no parity
1
odd
2
even
8.7.6. RS232 operation mode
Command format:
SET●/SYS/MB/RS232.Rs232Mode={0|1|2}
Response format:
pw●/SYS/MB/RS232.Rs232Mode={0|1|2}
Example:
> SET●/SYS/MB/RS232.Rs232Mode=1
< pw●/SYS/MB/RS232.Rs232Mode=1
Summary of Contents for UMX-TPS-TX120