
147
INSTALLER SETTING
146
INSTALLER SETTING
ENGLISH
Low Noise Mode Priority setting (air conditioner / DX ventilator)
It is the function to set the low noise mode control main agent. (It is the function to set that only
one of the outdoor unit / remote controller can control the low noise operation.)
• You can set the following setting values using [<,>(left/right)] button.
Value
Description
RMC
Ignore the outdoor unit PCB’s low noise operation Switch Setting value
- Function setting – remote controller low noise operation time menu de-
activation
ODU(default)
It is controlled in the outdoor unit itself according to the outdoor unit
PCB’s low noise operation Switch Setting value
- Function setting – remote controller low noise operation time menu de-
activation
Human detection sensor (air conditioner)
It is the function to set whether to install human detection sensor and operation standard value.
• In the installer setting list, after selecting human detection sensor setting category, if you press
[OK] button, it moves to the detail screen.
• You can set the following setting values for each category using [<,> (left/right)] button.
Value
Description
Installation status
Not installed, basic installation, 90º rotation installation
Detection result sending cycle
5 s, 30 s, 1 min., 3 min.
Sensitivity setting
Standard, low sensitivity, high sensitivity
Temperature control option
Step 0 : Keeps the product running and uses the tem-
perature power saving function.
Step 1 : The operation of indoor units is stopped by
using the temperature power saving function.
Detection Area Setting
Indoor floor area detection, 6X6, 12X6
Summary of Contents for PREMTB100
Page 82: ......