43
TIMER SETTING
ENGLISH
42
LOCK SETTING
LOCK SETTING
How to enter lock setting
• In the menu screen, press [<,>(left/right)] button to select “lock setting” category, and press
[OK] button to move to the lock setting list screen.
• In the lock setting list, if you press [
∧
,
∨
(up/down)] button, you can turn on/off the correspon-
ding lock function.
Lock setting – all, on/off, mode, temperature range lock
• It is the function to lock the button operation of the remote controller so that children or other
persons cannot use it without permission.
• It is the function to limit the desired temperature range that can be set in the wired remote controller.
OK
TIMER SETTING
Timer entrance and setting method
• In the menu screen, press [<,>(left/right)] button to select the timer category, and press [OK]
button to move to the timer setting list screen.
• In the timer setting list screen, press [
∧
,
∨
(up/down)] button to select the timer to set, and
press [OK] button to move to the detail screen.
• After setting the value, when you press [OK] button, the timer is activated.
• After setting the value, if you press [Back] button, the changed value will not be applied.
OK
Lock
Description
All lock
It locks all button operation of the remote controller.
On/Off lock
It locks the On/Off button operation of the remote controller.
Mode lock
It locks the operation mode button operation of the remote controller.
Temperature range
lock
It is the function that can limit the range of the desired temperature that
can be set in the wired remote controller.
- Single: Lower limit : 16~30 °C (60~86 °F)
Upper limit : 16/18~30 °C (60/64~86 °F)
- Dual : Cooling : 50~99 °F (10~37.5 °C)
Heating : 40~90 °F (4~32 °C)
NOTE
!
In the central controller, when the central control temperature range lock is set, the wired
remote controller’s temperature lock setting is cleared.
The temperature change by external equipment is reflected regardless of the remote
controller temperature range lock.