![LG Multi V 5 Service Manual Download Page 145](http://html.mh-extra.com/html/lg/multi-v-5/multi-v-5_service-manual_1892770145.webp)
145
Error Codes
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
ERROR CODES
Please refer to the Safety Precautions on pages 4-7 for more detail to prevent injury or death regarding the operation and service
troubleshooting of the Multi V product.
WARNING
Error No. 21, continued.
Measuring the resistance between
each compressor terminal.
Check DC link connections.
R
S
T
* Heat Sink
Screws.
Compressor wiring
connections.
P and N Terminals.
Images here are representative of system
components. Actual component appearance
depends on model and system type.
Cause Check
Checklist
App.
Check Point
Normal
Abnormal
Defective
Parts
Under Voltage (15V)
15V Voltage Measurement
(Inverter connector)
Voltage
14.5V ~ 15.5V
9Ļ
Inverter PCB
A2 (Power ON)
Inverter PCB
Damaged
Check Inverter PCB appearance
Appearance
Good
Damage
Inverter PCB
B1 (Power Off)
Measure 5V,15V line
5V, 15V Resistance
NĹ
NĻa
IGBTM (Check IGBT)
P-U,V,W / N-U,V,W 0.38V ~ 0.7V
Non-normal
Inverter Drive Circuit
(Check diode)
Diode
0.38V ~ 0.7V
Non-normal
Table 78: Error No. 21 Checkpoint Details.
Figure 72: Two Compressor Additional Check Procedure (Same Capacity Inverter Only).
Inv.1
- CH21
Inv.2
Comp.1
Comp.2
Inv.1
- CH21
Inv.2
Comp.1
Comp.2
Inv.1
Inv.2
- CH21
Comp.1
Comp.2
Standard Connection.
Example: Inverter 1, CH21
displayed.
If Inverter 2 has CH21 displayed,
then Comp. 1 is defective.
If Inverter 1 consistently displays
CH21, then Inverter 1 is defective.
Cross Connections after Operation.
or