TROUBLESHOOTING
Plasma Training
55
Troubleshooting
Z-SUSTAIN TROUBLESHOOTING
Check the output of X1 (normal is 100 MHZ). The DC/DC converter makes 5V,Va,Vs,Vset_up,Vsc which
is essential for each B/D. There is no separated DC/DC B/D in model our later plasma models. They
are embedded DC/DC circuits as part of another PCB as seen below.
Check here with DMM (either forward or reverse)
DMM +
DMM -
Y_DRIVE PCB
NOTE:
Use a DVM as shown below set to diode check either forward or reverse bias to check the drive IC.