Plasma Training
128
CableCARD M-Card
CABLECARD M-CARD
Introduction
This section provides an overview of the SA CableCARD Diag Screen, including the fields and parameters
that are included in the screen. This screen provides information that identifies the current status for
the CableCARD module.
Performing Tasks
By accessing this screen, you can perform the following tasks:
· Determine the hardware model and version number for the CableCARD module.
· Determine the MAC address for the CableCARD module.
· Determine the version of the operating system that is currently loaded onto the CableCARD module.
Example:
Scientific Atlanta CableCARD(tm)
Diagnostics
------------
H/W Model:
0600
Version:
0010
MAC addr:
00:02:DE:81:F1:0E
Mode:
Boot Time
Mon Sep 1 2003, 12:01:52 AM GMT
Current Time
Thu Mar 2 2006, 5:31:01 PM GMT
Generic Host Diagnostics
Heap Size:
1024 kB
Mem Free
: 1024 kB
Bldr Ver:
114
OS Ver:
01.00.24
Group Id:
0xFFFF
BFS:
Received
Current resource status:
C3F1DBF
Screen Fields and Values
Field Name
Description
Possible Values
H/W Model
The hardw are model number associated w ith
CableCARD module
• 600
—for SCARDs
•
800
—for MCARDs
MAC addr
The RF netw ork adapter MAC address that is used by
the DNCS
• [CableCARD-dependent]]
Mode
The operations mode of CableCARD
• SMODE
—indicates a single stream-
capable mode (SCARD or MCARD can
function in SMODE)
•
MMODE
—indicates a multistream-
capable CableCARD (MCARD are only
capable of functioning in MMODE)
Boot Time
The date and time that the system w as last booted
• [Date. Tim e]
Current Time
The current date and time
• [Date, Tim e]
Heap Size
The total segment of memory claimed by a program
• 1024 KB
Mem Free
The amount of memory not currently in use
• [Size varies dynamically]
Bldr Ver
The bootloader version for the CableCARD module
• [CableCARD-dependent]
OS Ver
The current operating system version for the
CableCARD module
• [CableCARD-dependent] Example
:
01.00.24
Group Id
The identification value for the group assigned by the
DNCS for CVT dow nload
• [Hexadecimal value]
BFS
An indication of w hether or not the CableCARD
receives the root directory from the DNCS
• Received
—desired value
•
Not Received
Current Resource Status
The status of the resources received (present) and
established (opened) sessions
• [Hexadecimal value]