Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
873
8400 StateLine C | Reference manual
Function library
System blocks | LS_ParReadWrite_1-3
Internal conversion
If arithmetic modes 1 ... 3 are selected in
C01093
, the input value / read parameter value is
internally converted via parameterisable factors.
Division is not remainder considered.
[16-28] Internal conversion for write access
[16-29] Internal conversion for read access
C01094
: Numerator
C01095
: Denominator
Parameter value to be written
Input value
[32]
Numerator
[16]
Denominator
[16]
-------------------------------------------
⋅
=
C01094
: Numerator
C01095
: Denominator
Output value
[32]
Read parameter value
Numerator
[16]
Denominator
[16]
-------------------------------------------
⋅
=