8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00593
C00593
C00594
Parameter | Name:
C00593 | Resp. to CANx_IN monitoring
Data type: UNSIGNED_8
Index: 23982
d
= 5DAE
h
Configuration of monitoring of the CAN interface (group 2)
System bus "CAN on board"
Selection list
0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes
Lenze setting
Info
C00593/1
0: No Reaction
Response if the monitoring time set in
C00357/1
for the
reception of the PDO CAN1_IN is exceeded.
C00593/2
0: No Reaction
Response if the monitoring time set in
C00357/2
for the
reception of the PDO CAN2_IN is exceeded.
C00593/3
0: No Reaction
Response if the monitoring time set in
C00357/3
for the
reception of the PDO CAN3_IN is exceeded.
;
Read access
;
Write access
CINH
PLC STOP
No transfer
;
COM
MOT
Scaling factor: 1
Parameter | Name:
C00594 | Resp. to control word error
Data type: UNSIGNED_8
Index: 23981
d
= 5DAD
h
Configuration of device control monitoring
Selection list
0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
5 Warning
Subcodes
Lenze setting
Info
C00594/1
1: Fault
Response if error bit 14 in the CAN control word is set.
C00594/2
1: Fault
Response if error bit 14 in the MCI control word is set.
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1