Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
423
8400 StateLine C | Reference manual
Diagnostics & error management
Error messages of the operating system
dH09: EEPROM power section [xx.0400.00009]
dH10: Fan failure [xx.0400.00016]
dH68: Adjustment data error CU [xx.0400.00104]
dH69: Adjustment data error BU [xx.0400.00105]
US01: User error 1 [xx.0980.00001]
US02: User error 2 [xx.0981.00002]
Response
(Lenze setting printed in bold)
0: No Reaction
:
1: Fault
2: Trouble
3: TroubleQuickStop
4: WarningLocked
5: Warning
6: Information
Cause
Remedy
Device error
Consultation with Lenze required.
Response
(Lenze setting printed in bold)
Setting:
C00566
(
;
Adjustable response)
;
0: No Reaction
;
1: Fault
2: Trouble
3: TroubleQuickStop
4: WarningLocked
:
5: Warning
6: Information
Cause
Remedy
The device fan has failed.
Possible causes:
• The short-circuit check of the fan connection has
tripped.
• The speed monitoring of the fan has tripped.
• Check the fan for short-circuit.
• Clean the fan.
Response
(Lenze setting printed in bold)
0: No Reaction
:
1: Fault
2: Trouble
3: TroubleQuickStop
4: WarningLocked
5: Warning
6: Information
Cause
Remedy
Device error
Consultation with Lenze required.
Response
(Lenze setting printed in bold)
0: No Reaction
:
1: Fault
2: Trouble
3: TroubleQuickStop
4: WarningLocked
5: Warning
6: Information
Cause
Remedy
Device error
Consultation with Lenze required.
Response
(Lenze setting printed in bold)
Setting:
C00581/1
(
;
Adjustable response)
:
0: No Reaction
;
1: Fault
;
2: Trouble
;
3: TroubleQuickStop
;
4: WarningLocked
;
5: Warning
;
6: Information
Cause
Remedy
User error 1 has been tripped via the
bSetError1
input of
the
LS_SetError_1
system block.
User-defined.
Response
(Lenze setting printed in bold)
Setting:
C00581/2
(
;
Adjustable response)
:
0: No Reaction
;
1: Fault
;
2: Trouble
;
3: TroubleQuickStop
;
4: WarningLocked
;
5: Warning
;
6: Information
Cause
Remedy
User error 2 has been tripped via the
bSetError2
input of
the
LS_SetError_1
system block.
User-defined.