Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
71
8400 StateLine C | Reference manual
Commissioning
PC manual control
4. To acknowledge the note and activate PC manual control:
Click the
Activate PC manual control
button.
• The controller is inhibited via device command (
C00002/16
).
• The
PC manual control
operator dialog is displayed.
PC manual control operator dialog
On the left-hand side, the
PC manual control
operator dialog includes control elements
which serve to select various control functions. On the right-hand side, setpoint and status
displays are provided for diagnostic purposes:
The execution of the various functions is described in the following chapters.
Note!
PC manual control can be exited any time by clicking the
Close
button.
If you exit PC manual control or change to another tab, the controller is inhibited
via device command (
C00002/16
), i.e. the motor becomes torqueless and is
coasting unless it already is at standstill.