8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00507
610
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
C00507
C00516
Parameter | Name:
C00507 | Current password protection
Data type: UNSIGNED_16
Index: 24068
d
= 5E04
h
From version 06.00.00
Display of the currently active device access protection
Device access protection
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Only access to user menu
Bit 1 Parameter write protection
Bit 2 Parameter read protection
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Memory module binding on
Subcodes
Info
C00507/1
Password protection - all communication channels
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Parameter | Name:
C00516 | Checksums
Data type: UNSIGNED_32
Index: 24059
d
= 5DFB
h
This code is for device-internal use only and must not be written to by the user!