![Lenovo x3550 M4 Installation And Service Manual Download Page 561](http://html.mh-extra.com/html/lenovo/x3550-m4/x3550-m4_installation-and-service-manual_203258561.webp)
5.
Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
•
806f050d-0402ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 2)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0402ffff or 0x806f050d0402ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4. Check backplane cable connection.
5.
Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
•
806f050d-0403ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 3)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0403ffff or 0x806f050d0403ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Appendix A. Integrated management module II (IMM2) error messages
547
Summary of Contents for x3550 M4
Page 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Page 6: ...iv System x3550 M4 Installation and Service Guide ...
Page 178: ...164 System x3550 M4 Installation and Service Guide ...
Page 322: ...308 System x3550 M4 Installation and Service Guide ...
Page 828: ...814 System x3550 M4 Installation and Service Guide ...
Page 986: ...972 System x3550 M4 Installation and Service Guide ...
Page 990: ...976 System x3550 M4 Installation and Service Guide ...
Page 1005: ......