![Lenovo x3550 M4 Installation And Service Manual Download Page 426](http://html.mh-extra.com/html/lenovo/x3550-m4/x3550-m4_installation-and-service-manual_203258426.webp)
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0522
User Response
Complete the following step to solve PCI I/O resource errors:
1. Go to F1 Setup-> System Settings-> Device and I/O ports-> PCI 64 bit Resource and choose
enable.
•
80070214-2201ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (TPM Lock)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702142201ffff or 0x800702142201ffff
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
CIM Information
Prefix:
PLAT
ID:
0522
User Response
1. Update the server firmware (see Recovering the server firmware).
2. If the problem persists, (trained technician only) replace the system board (see Removing the
system board and Installing the system board).
•
80070219-0701ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (SysBrd Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702190701ffff or 0x800702190701ffff
412
System x3550 M4 Installation and Service Guide
Summary of Contents for x3550 M4
Page 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Page 6: ...iv System x3550 M4 Installation and Service Guide ...
Page 178: ...164 System x3550 M4 Installation and Service Guide ...
Page 322: ...308 System x3550 M4 Installation and Service Guide ...
Page 828: ...814 System x3550 M4 Installation and Service Guide ...
Page 986: ...972 System x3550 M4 Installation and Service Guide ...
Page 990: ...976 System x3550 M4 Installation and Service Guide ...
Page 1005: ......
Page 1006: ......