![LeCroy 9300C Series Operator'S Manual Download Page 241](http://html1.mh-extra.com/html/lecroy/9300c-series/9300c-series_operators-manual_1866306241.webp)
D
–7
Parameter Measurement
P a r a m e t e r a n d w h a t i t d o e s
Definition
Notes
dur
For single sweep waveforms,
dur
is 0; for
sequence waveforms: time from first to
last segment’s trigger; for single
segments of sequence waveforms: time
from previous segment’s to current
segment’s trigger; for waveforms
produced by a history function: time from
first to last accumulated waveform’s
trigger.
Time from first
to last
acquisition — for
average,
histogram or
sequence
waveforms
duty
Duty cycle: Width as percentage of
period.
width/period
(See Fig. D–2)
f80–20%
Fall 80–20 %: Duration of pulse
waveform's falling transition from 80% to
20%, averaged for all falling transitions
between the cursors.
Average duration
of falling
80–20 %
transition
On signals
NOT
having two
major levels (triangle or saw-
tooth waves, for example), top
and base can default to
maximum and minimum, giving,
however, less predictable
results.
f@level
Fall at level: Duration of pulse
waveform's falling edges between
transition levels.
Duration of
falling edge
between
transition levels
On signals
NOT
having two
major levels (triangle or saw-
tooth waves, for example), top
and base can default to
maximum and minimum, giving,
however, less predictable
results.
Fall time: Measures time between two
specified values on falling edges of a
waveform. Fall times for each edge are
averaged to produce final result.
Arguments
Threshol
d
Remote Lower
Limit
Upper
Limit
Default
Lower
low
1 %
45 %
10 %
fall
Upper
high
55 %
99 %
90 %
Time at lower
threshold
-
Time at upper
threshold
averaged over
each falling edge
(See Fig. D–1)
On signals
NOT
having two
major levels (triangle or saw-
tooth waves, for example), top
and base can default to
maximum and minimum,
giving, however, less
predictable results.
Summary of Contents for 9300C Series
Page 1: ...Operator s Manual LeCroy 9300C Series Digital Oscilloscopes Revision A January 1998 ...
Page 8: ...1 3 billed for parts and labor related to the repair work and for shipping ...
Page 18: ...4 1 4 Introduction to the Controls Two Channel Front Panel ...
Page 19: ...4 2 Introduction to the Controls Four Channel Front Panel ...
Page 92: ......
Page 111: ...11 3 Dual Quad ...
Page 112: ...11 4 Display Parameter s XY only ...
Page 113: ...11 5 XY Single XY Dual ...
Page 138: ...12 21 Ø FLASH UPDATE Offering the Update from and Update Program menus illustrated next page ...
Page 139: ...12 22 UTILITIES The full screen warning message shown when FLASH UPDATE has been selected ...
Page 142: ...13 2 WAVEFORM STORE RECALL ...
Page 182: ......
Page 189: ...A 15 9344C Series 9350C Series 9354C Series 9354CTM 50 000x 9344CL 9350CL 9354CL 100 000x ...
Page 252: ...E 6 Appendix E ...
Page 275: ...Index 9370C 9374C Series A 18 9384C Series A 24 Zoom menu 10 7 Zoom of Math Functions 10 1 ...