B
–3
Enhanced Resolution
of the overflowed data — the filter impulse response length —
would be incorrect. This is because in some circumstances an
overflow may be a spike of only one or two samples, and the
energy in this spike may not be enough to significantly affect the
results. It would then not be desirable to disallow the whole
trace.
When to Use It?
In general, enhanced resolution is used to replace the averaging
function in situations where the data record has a single-shot or
slowly repetitive nature and averaging cannot be used.
There are two particular situations in which enhanced resolution
is especially useful. One is when the signal is noticeably noisy
and measurements of the noise are not required. The signal can
be “cleaned up” by using the enhanced resolution function. The
other is when — even if the signal is not particularly noisy —
high-precision measurements of the waveform are required
(when using Expand with high vertical gain, for example).
Enhanced resolution will then increase the resolution of the
measurements.
The examples on the following pages illustrate how enhanced
resolution can be used.
Summary of Contents for 9300C Series
Page 1: ...Operator s Manual LeCroy 9300C Series Digital Oscilloscopes Revision A January 1998 ...
Page 8: ...1 3 billed for parts and labor related to the repair work and for shipping ...
Page 18: ...4 1 4 Introduction to the Controls Two Channel Front Panel ...
Page 19: ...4 2 Introduction to the Controls Four Channel Front Panel ...
Page 92: ......
Page 111: ...11 3 Dual Quad ...
Page 112: ...11 4 Display Parameter s XY only ...
Page 113: ...11 5 XY Single XY Dual ...
Page 138: ...12 21 Ø FLASH UPDATE Offering the Update from and Update Program menus illustrated next page ...
Page 139: ...12 22 UTILITIES The full screen warning message shown when FLASH UPDATE has been selected ...
Page 142: ...13 2 WAVEFORM STORE RECALL ...
Page 182: ......
Page 189: ...A 15 9344C Series 9350C Series 9354C Series 9354CTM 50 000x 9344CL 9350CL 9354CL 100 000x ...
Page 252: ...E 6 Appendix E ...
Page 275: ...Index 9370C 9374C Series A 18 9384C Series A 24 Zoom menu 10 7 Zoom of Math Functions 10 1 ...