User Manual for ELD5 Servo
(V1.00)
www.leadshine.com
49
Driver inner fault
/
replace the driver with a new one
Error
code
Main
Extra
Display:
“
”
Content:
temperature detection circuit error
Cause
Confirmation
Solution
Vdc/GND under-voltage
Check the voltage of
Vdc/GND terminal
Make sure voltage of Vdc/GND in proper range
Driver inner fault
/
replace the driver with a new one
Error
code
Main Extra
Display:
“
”
Content:
control power under-voltage
Cause
Confirmation
Solution
Vdc/GND under-voltage
Check the voltage of
Vdc/GND terminal
Make sure voltage of Vdc/GND in proper range
Driver inner fault
/
replace the driver with a new one
Error
code
Main
Extr
a
Display:
“
”
Content:
DC bus over-voltage
Cause
Confirmation
Solution
Vdc/GND over-voltage
Check the voltage of Vdc/GND
terminal
Make sure voltage of Vdc/GND in
proper range
Inner brake circuit damaged
/
replace the driver with a new one
Driver inner fault
/
replace the driver with a new one
Error
code
Main
Extra
Display:
“
”
Content
: DC bus under-voltage
Cause
Confirmation
Solution
Vdc/GND under-voltage
Check the voltage of Vdc/GND
terminal
Make sure voltage of Vdc/GND in
proper range
Driver inner fault
/
replace the driver with a new one
Error
code
Main
Extra
Display:
“
”
Content:
over-current
Cause
Confirmation
Solution
Short of driver output wire
Short of driver output wire, whether
short circuit to PG ground or not
Assure driver output wire no short
circuit, assure motor no damage
Abnormal wiring of motor
Check motor wiring order
Adjust motor wiring sequence
Short of IGBT module
Cut off driver output wiring, make
srv_on available and drive motor,
check whether over-current exists
replace the driver with a new one
abnormal setting of control
parameter
Modify the parameter
Adjust parameter to proper range
abnormal setting of control
command
Check control command whether
command changes too violently or
Adjust control command: open
filter function