reverse the direction of rotation
Pr0.07* Command Pulse Input Mode Setup
Range
unit default
Related
control mode
0 -3
-
0
P
Pr0.06
Pr0.07
Command Pulse Format
Signal
Positive
Direction
Command
Negative
Direction
Command
0
0
Pulse + sign
Pulse
sign
1 or 3
90 phase difference
2-phase pulse(A phase +B
phase)
Pulse
sign
2
Positive direction pulse +
negative direction pulse
Pulse
sign
1
0
Pulse + sign
Pulse
sign
1 or 3
90 phase difference
2-phase pulse(A phase +B
phase)
Pulse
sign
2
Positive direction pulse +
negative direction pulse
Pulse
sign
Command pulse input signal allow largest frequency and smallest time width
PULS/SIGN Signal Input I/F
Permissible Max.
Input Frequency
Smallest Time Width
t1
t2
t3
t4
t5
t6
Pulse
series
interface
Long distance interface
500kpps
2
1
1
1
1
1
Open-collector output
200kpps
5
2.5
2.5
2.5
2.5
2.5
Pr0.08 Command pulse counts per one motor
revolution
Range
unit
default
Related
control mode
0-32767
pulse
0
P
Set the command pulse that causes single turn of the motor shaft.
When this setting is 0 ,Pr009 1
st
numerator of electronic gear and Pr0.10 Denominator of electronic
Gear become valid.
Pr0.09 1st numerator of electronic gear
Range
unit default
Related
control mode
1-32767
-
1
P
Set the numerator of division/multiplication operation made according to the command pulse input.
Pr0.10 denominator of electronic gear
Range
unit default
Related
control mode
1-32767
-
1
P
Set the denominator of division/multiplication operation made according to the command pulse
input.
Pr0.09
Pr0.10
Command division/multiplication operation