User Manual for ELD5 Servo
(V1.00)
www.leadshine.com
40
Pr4.13* Output selection SO4
Range
unit
Related
control mode
0-00FFFFFFh
-
00000303h
(328964)
P
S T
Assign functions to SO1 outputs.
This parameter use 16 binary system do setup, as following :
00- - - - * * h: position control
00- - * * - - h: velocity control
00* * - - - - h: torque control
Please at [**] partition set up function number.
For the function number, please refer to the following Figure.
Signal name
symbol
Setup value
Invalid
-
00h
Alarm output
Alm
01h
Servo-Ready output
S-RDY
02h
Eternal brake release signal
BRK-OFF
03h
Positioning complete output
INP
04h
At-speed output
AT-SPPED
05h
Zero-speed detection output
ZSP
07h
Velocity coincidence output
V-COIN
08h
Positional command ON/OFF output
P-CMD
0Bh
Speed command ON/OFF output
V-CMD
0Fh
Pr4.22 Analog input 1 (AI1) offset setup
Range
unit default
Related
control mode
-5578 -5578
-
0
S
Set up the offset correction value applied to the voltage fed to the analog input 1.
Pr4.23 Analog input 1 (AI1) filter
Range
unit
default
Related
control mode
0-6400
0.01ms
0
S
Set up the time constant of 1st delay filter that determines the lag time behind the voltage applied to
the analog input 1.
Pr4.31 Positioning complete range
Range
unit
default
Related
control mode
0 -10000
Encoder unit
10
P
Set up the timing of positional deviation at which the positioning complete signal (INP1) is output.
Pr4.32 Positioning complete range
Range
unit
default
Related
control mode
0 -3
command unit
10
P
Select the condition to output the positioning complete signal (INP1).
Setup value
Action of positioning complete signal
0
The signal will turn on when the positional deviation is smaller than Pr4.31
[positioning complete range].
1
The signal will turn on when there is no position command and position
deviation is smaller than Pr4.31 [positioning complete range].
2
The signal will turn on when there is no position command, the zero-speed
detection signal is ON and the positional deviation is smaller than Pr4.31
[positioning complete range].
3
The signal will turn on when there is no position command and the positional