User Manual for ELD5 Servo
(V1.00)
www.leadshine.com
45
4.2.7
【
Class 6
】
Special Setup
6
Command pulse sum
24
Encoder positional
deviation[encoder
unit]
36
Safety condition
monitor
9
Control mode
Pr5.29*
Baud rate setup of RS232
communication
Range
unit
default
Related
control mode
0-6
-
5
P
S T
You can set up the communication speed of RS232.
Pr5.30*
Baud rate setup of RS485
communication
Range
unit
default
Related
control mode
0-6
-
2
P
S T
You can set up the communication speed of RS485.
Set value
Baud rate Set value Baud rate
0
2400bps
4
38400bps
1
4800bps
5
57600bps
2
9600bps
6
115200bps
3
19200bps
Baud rate error is
2400-38400bps±5% ,57600-115200bps±2%
Pr5.31*
Axis address
Range
unit
default
Related
control mode
0-127
-
1
P
S T
During communication with the host (e.g. PC) to control multiple shafts, the shaft being accessed by
the host should be identified.
Notice: when using RS232/RS485, the maximum valid value is 31.
Pr5.35*
Front panel lock setup
Range
unit
default
Related
control mode
0-1
-
0
P
S T
Lock the operation on the front panel.
Setup value
content
0
No limit on the front panel operation
1
Lock the operation on the front panel
Pr6.03
JOG trial run command torque
Range
unit default
Related
control mode
0 -100
%
0
T
You can set up the command speed used for JOG trial run (torque control).
Pr6.04
JOG trial run command speed
Range
unit
default
Related
control mode
0-500
r/min
300
P
S T
You can set up the command speed used for JOG trial run (velocity control).