70
APPENDIX B
SPECIFICATIONS
Ps1 Output
Pressure function
range:
0.1 to 42 inHg
resolution:
0.001 inHg
accuracy:
0.002 inHg
Altitude function
range:
-4000 ft. to 60,000 ft.
resolution:
1 foot
accuracy:
2 ft. @ 0 ft.
6 ft. @ 35,000 ft.
12 ft. @ 50,000 ft.
Climb function
range:
0 ft/min to 25,000 ft/min
resolution:
1 ft/min
accuracy:
1% of rate of climb
Pt Output
Pressure function
range:
0.1 to 60 inHg
resolution:
0.001 inHg
accuracy:
0.003 inHg
Airspeed function
range:
0 to 650 knots
resolution:
0.1 knots
accuracy:
0.5 knots @ 50 knots
0.25 knots @ 100 knots
0.05 knots @ 650 knots
Mach function
range:
0.0 to 3.0 Mach
resolution:
0.001 Mach
accuracy:
0.001 above 0.2
Mach
Ps2 Output
range:
0.1 to 42 inHg (Diff. to Ps1: +/-30.0 inHg)
resolution:
0.001 inHg
accuracy:
0.002 inHg
Power requirement
90-260 VAC, 47-440 Hz., 250 VA
Interfaces
RS232
Dimensions & weights
Main unit:
22” x 14” x 9” / 45 lbs
Remote unit:
7” x 8” x 2” / 1 lb.
Environmental specs:
Operating temp.
0
o
to50
o
C
Storage temp.
-25
o
to 75
o
C
Humidity:
5 to 95% non-condensing
Summary of Contents for 6600