63
Model:
6600
Serial#:
77123
Full scale:
Ps: 38 inHg
Pt: 60 inHg
Last Calibrated date:
June 25, 2007
Next Calibration due:
June 25, 2009
_______________________________________________________________________
CALIBRATION RESULTS
Ps1 Output
TEST POINT
AS FOUND
AS LEFT
DEVIATION
inHg
inHg
inHg
1. Vacuum
1.001
1.000
0.001
2. Fullscale
38.002
38.000
0.002
Ps2 Output
TEST POINT
AS FOUND
AS LEFT
DEVIATION
inHg
inHg
inHg
1. Vacuum
1.000
1.000
0.000
2. Fullscale
38.001
38.000
0.001
Pt Output
TEST POINT
AS FOUND
AS LEFT
DEVIATION
inHg
inHg
inHg
1. Vacuum
1.001
1.000
0.001
2. Fullscale
60.002
60.000
0.002
_______________________________________________________________________
VERIFICATION RESULTS
Ps1 Output
Ps2 Output
Pt Output
APPLIED DISPLAYED APPLIED DISPLAYED APPLIED DISPLAYED
inHg
inHg inHg
inHg
inHg
inHg
1.000
1.000
1.000
1.000
1.000
1.000
4.000
4.000
4.000
4.000
6.000
5.999
8.000
8.000
8.000
7.999
12.000
11.999
12.000
12.000
12.000
11.999
18.000
18.000
15.000
15.000
15.000
15.000
24.000
24.000
19.000
19.001
19.000
19.000
30.000
30.000
23.000
23.001
23.000
23.000
36.000
36.000
27.000
27.000
27.000
27.001
42.000
42.001
30.000
30.000
30.000
30.000
48.000
48.002
34.000
34.000
34.000
34.000
54.000
54.001
38.000
38.000
38.000
38.000
60.000
60.000
_______________________________________________________________________
Calibrated by: Date: June 25, 2008
Figure 6.1 Sample calibration sheet