66
Command Type
Description
PA
R
Actual Pt value in current units
RA
R
Actual Rate value in current units
SA
R
Actual Ps1 value in current units
DA
R
Actual Ps2 value in current units
PT
R
Read current Pt target value
PT=n
W
Set Pt target value to n
RT
R
Read current Rate target value
RT=n
W
Set Rate target value to n
ST
R
Read current Ps1 target value
ST=n
W
Set Ps1 target value to n
DT
R
Read current Ps2 target value
DT=n
W
Set Ps2 target value to n
PJ=n
W
Jog up (n=0) or down (n=1) Pt target
RJ=n
W
Jog up (n=0) or down (n=1) Rate target
SJ=n
W
Jog up (n=0) or down (n=1) Ps1 target
DJ=n
W
Jog up (n=0) or down (n=1) Ps2 target
PU
R
Read current Pt units (value returned: 1 to 9)
PU=n
W
Set Pt units as per following:
n
units
1
knots
2
mach
3
Pt inHg
4
Qc inHg
5
Pt mb
6
Qc mb
7
mph
8
kmph
9
EPR
SU
R
Read current Ps1 units (value returned: 1 to 4)
SU=n
W
Set Ps1 units as follows:
n
units
1
Feet
2
inHg
3
meters
4
mbar
DU
R
Read current Ps2 units (value returned: 1 to 8)