67
Command Type
Description
DU=n
W
Set Ps2 units as follows:
n
units
1
Diff. inHg
2
inHg
3
Diff. mbar
4
mbar
5
Feet
6
meters
7
knots
8
kmph
PM
R
Read current Pt mode
PM=n
W
Set Pt mode to Measure (1), Leak (2), Control (3)
SM
R
Read current Ps1 mode
SM=n
W
Set Ps1 mode to Measure (1), Leak (2), Control (3)
DM
R
Read current Ps2 mode
DM=n
W
Set Ps2 mode to Measure (1), Leak (2), Control (3)
ER
R
Read current error ; 0 if no error
L1
R
Read max. knots limit
L1=n
W
Set max. knots limit
L2
R
Read max. differential limit in inHg
L2=n
W
Set max. differential limit in inHg
L3
R
Read max. Mach limit
L3=n
W
Set max Mach limit
L4
R
Read max. altitude limit
L4=n
W
Set max. altitude limit
L5
R
Read min. altitude limit
L5=n
W
Set min. altitude limit
L6
R
Read max. altitude rate limit
L6=n
W
Set max. altitude rate limit
KR
R
Read current Knots rate
KR=n
W
Set Knots rate to n
PF
R
Read current profile point
PF=n
W
Set current profile point to n (xx.xx)