OPERATION OF L&L KILNS WITH A ONE-TOUCH™ (Deg F)
one-touch-operation-deg-f,pd
f
REV: 1/24/19
Page 12
2016
L&L Kiln Mfg, Inc. 505 Sharptown Rd, Swedesboro NJ 08085 P:856.294.0077 F:856.294.0070 [email protected] hotkilns.com
MEd
Medium (Heat up or Cool down rate)
OFF
No beeping when firing is complete. Or could be
that an option is off when setting options. Also used to show
that Cooling is off.
On
Beeps for 15 seconds at end of firing.
rA#
Ramp Number (rate per hour of temperature
increase or decrease). (# stands for numbers 1 through 8)
rStr
Restore default original values
SEG
Short for Segments. You can enter up to 8
segments in a program.
SLO
Slow (Heat up or Cool down rate)
SStP
Skip Step (used to advance to the next ramp)
StOP
The kiln is at idle and ready to be programmed.
Message alternates with the current kiln temperature.
CUS1
,
CUS2
,
CUS3
,
CUS4
Custom program
number displayed.
18. ERROR CODES
tC FAIL
tC
alternating with
FAIL
indicates
the thermocouple has failed. Replace the defective
thermocouple. To clear the error, press any key.
Errd
Displayed whenever the kiln temperature is 100°F
(38°C) above the traveling set-point, which is the current
desired temperature in the kiln. The traveling set-point will
increase or decrease according to the programmed rate.
Err1
Displayed whenever the kiln temperature is rising
during an up ramp slower than 15°F/hr. (9°C/hr) If this rate
continues for 8 minutes the firing will be stopped.
Err1
may be an indication that the elements are worn or that a
relay has stopped working.
ErrP
Displayed whenever there is a power interruption
that is long enough to stop the firing. If the power
interruption is brief, the kiln will continue to fire when power
is restored; in this case, there will be no indication of a
power failure. To clear the error, press any key.
ErrF
Displayed whenever the kiln temperature is
decreasing during a down ramp slower than 15°F/hr (9°C/
hr). If this rate continues for 8 minutes the firing will be
stopped.
ErrF
may be an indication that a relay has stuck
in the on position.
tC--
The red and yellow thermocouple wires are reversed.
19. SOFTWARE VERSION
These instructions apply to software version
LL-G
for the
Cone 6 version of the control or
1t-1
for the Cone 10
version of the control. You will see this code flash when you
first turn on the control.
20. CENTIGRADE INSTRUCTIONS
These instructions are available in a Fahrenheit version. Go
to hotkilns.com/basic-one-touch-c
21. SPECIFICATIONS