OPERATION OF L&L KILNS WITH A ONE-TOUCH™ (Deg F)
one-touch-operation-deg-f,pd
f
REV: 1/24/19
Page 11
2016
L&L Kiln Mfg, Inc. 505 Sharptown Rd, Swedesboro NJ 08085 P:856.294.0077 F:856.294.0070 [email protected] hotkilns.com
2.
OFF
turns off the beeper.
3.
FULL
makes the beeper stay on until any button is
pushed.
4.
On
makes the beeper sound 15 times and then turn
off.
5. If you don’t want to change this option then press
ENTER.
16.2.2 MAXIMUM TEMPERATURE
1. On a Cone 6 Version (School-Master): Maximum
Temperature (Deg C)
1700
,
2000
, and
2280
are options.
2. On a Cone 10 Version (Liberty-Belle, Doll, Fuego,
Robin): Cone 10 models have a preset maximum
temperature limit of
2350
and you will not see the
“Maximum Temperature” option come up.
16.2.3 TEMPERATURE INDICATION
1.
oF
(Deg F) or
oC
(Deg C).
2. When you are in Deg C, you will always see a little dot
in the display at the bottom right to remind you.
3. Use the
UP
or
DOWN
button to change the value and
then press
ENTER.
16.2.4 THERMOCOUPLE OFFSET
1.
OFFS
(+/- deg F)
2. Display shows
OFFS
.
3. Press the
UP
arrow to enter a positive offset.
4. Press the
DOWN
arrow to add a negative sign to the
offset, and then the
UP
arrow to add negative offset to
the control.
5. The control comes with a pre-prog18 Deg F
offset to compensate for the thermocouple protection
tube.
6. Note: if you first press the
DOWN
button you can only
set a negative value or if you first press the
UP
button
you can only enter a positive value.
7. You can go back and change this later if you make a
mistake.
Note: you can adjust how the kiln fires by adjusting the
thermocouple offset. For instance, if your kiln if firing cool
(according to a witness cone placed in the kiln) then you can
add positive Offset. If it is firing hot then you can reduce the
offset or put in a negative offset. Try doing this in 5 degree
increments.
17. MESSAGES & DISPLAYS
CndL
Candle Time (this is a low temperature firing used
to dry moisture from the clay)
COnE
Cone to fire to
COOL
Cool down rate.
OFF
(natural cooling),
SLO
(Slow),
MEd
(Medium),
FASt
(Fast)
CPLt
Firing Cycle Complete (firing time is alternately
displayed).
dELA
Delay. Displays when entering the delay time
(hour:minutes) until the start of the firing.
DLy
Delay. Alternates with the remaining delay time
until the start of the kiln.
°F#
Segment temperature in °F–Set temperature for a
user program. (# stands for numbers 1 through 8)
°C#
Segment temperature in °C – Set temperature for
a user program. A decimal point will display in lower right
corner. (# stands for numbers 1 through
8
)
EdIt
Edit the default options (beeping at complete,
temperature scale, cone fire, delay, maximum programmable
temperature)
ErrP
There has been a power interruption that has
stopped the firing. Press any button to clear.
FASt
Fast (Heat up or Cool down rate)
FIrE
Ready to fire current program. Press
START
to
begin firing.
FULL
Beeps continuously at end of firing until a button is
pressed.
HtUP
Heat up rates.
SLO
(Slow),
MEd
(Medium),
FASt
(Fast)
HLd
Hold or Soak time at peak temperature
HLd#
Soak time in hours:minutes at a hold temperature.
(# stands for numbers
1
through
8
)
IdLE
This shows up when the control is not firing or is
not being programmed. Message alternates with the current
kiln temperature. Similar to
StOP.
1t-1
This comes on when you first turn on the control if
it is a Cone 10 control.
LL-G
This comes on when you first turn on the control if
it is a Cone 6 control.