OPERATION OF L&L KILNS WITH A ONE-TOUCH™ (Deg F)
one-touch-operation-deg-f,pd
f
REV: 1/24/19
Page 7
2016
L&L Kiln Mfg, Inc. 505 Sharptown Rd, Swedesboro NJ 08085 P:856.294.0077 F:856.294.0070 [email protected] hotkilns.com
12.2.1 Slow Glaze
∆06 Slow Glaze – SEGS–3 (3 segments)
Seg 1- 0.45 Hrs RA1 - 400ºF º F1–250ºF HOLD- 00.00
Seg 2- 3.31 Hrs RA2 - 400ºF º F2–1572ºF HOLD- 00.00
Seg 3- 2.00 Hrs RA3 - 128ºF º F3–1828ºF HOLD- 00.00
TOTAL FIRING TIME = 5.31 HRS
12.2.2 Medium Glaze (Default Glaze Program)
∆06 Medium Glaze – SEGS–3 (3 segments)
Seg 1- 0.29 Hrs RA1 - 400ºF º F1–185ºF HOLD- 00.00
Seg 2- 3.76 Hrs RA2 - 400ºF º F1–1572ºF HOLD- 00.00
Seg 3- 1.71 Hrs RA3 - 150ºF º F2–1828ºF HOLD- 00.00
TOTAL FIRING TIME = 5.17 HRS
12.2.3 Fast Glaze
∆06 Fast Glaze – SEGS–3 (3 segments)
Seg 1- 0.20 Hrs RA1 - 570ºF º F1–185ºF HOLD- 00.00
Seg 2- 2.43 Hrs RA2 - 570ºF º F2–1572ºF HOLD- 00.00
Seg 3- 1.28 Hrs RA3 - 200ºF º F3–1828ºF HOLD- 00.00
TOTAL FIRING TIME = 3.71 HRS
12.3 SIMPLE COOL DOWN SPEEDS
Note: These are entered as one of the simple options in the
Simple Programming (
COOL)
.
Cool Down options are as follows:
1. Slow = 125°F/hour
2. Med = 250°F/hour
3. Fast = 500°F/hour
13. CUSTOM RAMP/HOLD
PROGRAMMING
1. Each fully customizable program has eight segments.
2. Each segment has a ramp rate, a hold time and a
temperature set point.
3. Ramp Rate is some number of degrees centigrade per
hour either increasing or decreasing in temperature. For
example a ramp rate of
27
means that the program
will move from the temperature at the beginning of the
segment to the temperature at the end of the segment
at 27 degrees centigrade per hour.
4. Hold time is a time that the program holds the
temperature reached at the end of the segment. It can
be set for
00.00
and, in fact, in most cases is.
5. The temperature set point is the final temperature
intended to be reached in the segment.
6. At the end of the segment, i.e. when the program
reached the temperature set point and finishes any
hold time the control will move to the next segment. If it
is the last segment then the program will be complete
(
CPLt
).
13.1 REUSE A PREVIOUS PROGRAM
1. Start with the display reading
IdLE
and flashing a
temperature or
StOP
and temperature.
2. Select
CUSTOM
3. See
CUSt
4. Press
ENTER
5. You will see
CUS1
,
CUS2
,
CUS3
or
CUS4
.
6. These are the four custom programs.
7. You can scroll to other ones with the
UP
and
DOWN
button.
8. When the display shows the one you want to select
press
ENTER
.
9. After you have selected your program with
ENTER
press the
REVIEW
button.
10. This will scroll through all the segments so you can
see what is programmed in that custom program and
the end up with
FIrE
. Press
ENTER
when you see
FIrE
and the program will start.
13.2 CHANGING A PROGRAM (STEP BY STEP)
13.2.1 START
1. Start with the display reading
IdLE
and flashing a
temperature or
StOP
and temperature.
13.2.2 CHOOSE CUSTOM PROGRAMMING
1. Select
CUSTOM
2. See
CUSt
3. Press
ENTER