TROUBLESHOOTING AND REPAIR INSTRUCTIONS FOR L&L KILNS
troubleshoot-general.pdf
REV: 4/15/2017
Page 20
2017
L&L Kiln Mfg, Inc. 505 Sharptown Rd, Swedesboro NJ 08085 856.294.0077 F:856.294.0070 [email protected] hotkilns.com
CAUTION: The controller contains electronic components
which are sensitive to static electricity. Before handling
the controller dissipate any static charge you may have by
touching metal or a screw on the controller panel, the elec-
trical box, the kiln lid, or some other grounded object.
REPLACING DYNATROL
See this video:
hotkilns.com/replace-dynatrol
1) Unplug kiln or turn off the kiln at the fused disconnect
switch.
2) Remove the four #6 screws that hold the DynaTrol in
place from the front face of the control panel.
3) Open up the control box and hinge down for access (as
shown on page 2)
4) Pull off the spade connectors from all the connection
points on the back of the control. Loosen the screws that
hold down the thermocouple wires and pull out the wires
from under the screw heads. It is OK to remove the screws
if this is easier for you. First note where all the wires go.
These are all clearly marked with color coding on the Wiring
Diagram.
5) Pull old control out. Put new control in and screw in place
with the #6 mounting screws. Replace wires on proper
connectors.
6) Be careful to get the Red or Yellow of the thermocouple
wires to match the colors painted on the DynaTrol board.
Picture showing thermocouple wires installed on
DynaTrol. There is no need to wrap the thermocouple
wire around the screw head- although it is OK to
do so. However, do make sure the wire is tight and
secure UNDER the screw head.
7) Double check that the proper color coded wire goes to
the proper terminal.
Orange = OUT 1
Blue = OUT 2
Purple = OUT 3 (not on e18S, e23S, and e28S)
Gray = AC1
Green = CT
Brown = AC2
TC1 = TC1
TC2 = TC2
TC3 = TC3 (not on e18S, e23S, and e28S)
REPLACING ONE-TOUCH™
See this video:
hotkilns.com/replace-dynatrol
(Note the
process of changing a DynaTrol is very similar)
1) Unplug kiln or turn off the kiln at the fused disconnect
switch.
2) Remove the four #6 screws that hold the One-Touch™ in
place from the front face of the control panel.
3) Open up the control box and hinge down for access (as
shown on page 3)
4) Pull off the spade connectors from all the connection
points on the back of the control. Loosen the screws that
hold down the thermocouple wires and pull out the wires
from under the screw heads. It is OK to remove the screws
if this is easier for you. First note where all the wires go.
These are all clearly marked with color coding on the Wiring
Diagram.
5) Pull old control out. Put new control in and screw in place
with the #6 mounting screws. Replace wires on proper
connectors.
6) Be careful to get the Red or Yellow of the thermocouple
wires to match the colors painted on the control board.