Electrical connection
Note
the machine is not supplied with an electrical plug or cable, as the type of plug and
cable, will be dependant on the installation. A qualified electrician must carry out the
electrical installation.
Switch box open
Ground
Fitting the electrical cable.
The electrical cable is fitted as shown. The recomented cable
size 10.3 gauge for runs of up to 20’. For longer runs up to 50’use cable 8-3 gauge.
Recommended breaker size is 20 amps.
On the machine you will see a wire that is yellow and green, this is the ground wire, the
other colored wires are power. It does not matter what color combination you use. Green
and yellow is ground; all other wiring is power (there is no neutral). On single phase the
wiring can be interchanged as you wish; it would not affect the rotation of the motor. The
direction of rotation of machines with a single: phase supply is predetermined during
production.
Before starting the machine
1
/ Read and understand the instruction manual before operating the saw.
2
/ If you are still not thoroughly familiar with the operation of the saw get advice from a
qualified person.
3
/ Make sure the machine is properly grounded and that the wiring codes are followed.
4
/ Do not operate the machine while under the influence of drugs, alcohol, and medicine
or if tired.
5
/ Always wear eye protection, safety glasses or a safety shield, and hearing protection.
6
/Wear dust mask; long term exposure to the fine dust created by the saw is not healthy.
7
/ Remove your tie, rings, watch, and all jewelry. Roll up your sleeves, and never ware
loose clothing. You do not want anything to get caught in the saw.
8
/ Make sure that the guards are in place and use them at all times. The guards protect
you from coming in contact with the blade.
9
/ Make sure that the saw blade teeth point in the correct direction.
10
/ Stop the machine before removing the scrap piece from the table.
11
/ Always keep your hands and fingers away from the blade.
12
/ Make sure that you use the proper size and type of blade.
Ground /earth
Switch box open
Summary of Contents for TS SERIES
Page 2: ......
Page 8: ...8 TSS floor plan TS floor plan...
Page 45: ...45 Electrical circuit...
Page 49: ...49 BODY WITH PANEL AND REMOVABLE PANEL TS...
Page 51: ...51 BODY WITH PANEL TSS...
Page 55: ...55 34 36 37 38 LU 00 00 00 Rip fence TS...
Page 57: ...57 34 35 33 36 LUMF 00 00 00 Sliding table rip fence TSS...
Page 59: ...59 LVC1219 00 00 00 CIRCULAR SAW MITER FENCE TSS 4 LONG...
Page 61: ...61 LVC600 00 00 00 CIRCULAR SAW MITER FENCE OPTIONAL 2 LONG...
Page 63: ...63 MF1270 03 00 00 00 SLIDING TABLE MF L 1270 TSS...
Page 66: ...66 RC 00 00 00 T Scoring OPTIONAL TSS TS 44 45...
Page 68: ...68 RCD 00 00 00 Scoring unit with DADO OPTIONAL TSS TS...
Page 72: ...72 108 108 108 89 88 24 86 49 ST01 02 00 00 00 MAIN CIRCULAR SAW 1 PHASE MOTOR 2 2kW TSS TSS...