51
Select ON only if a closing safety sensor has been installed on the E.C. input (terminal 7).
The selection of this function is valid for both master and slave automations.
Select ON only if an opening safety sensor has been installed on E.O. input (terminal 6).
The selection of this function is valid for both master and slave automations.
Only if function S05 was set to ON.
Select ON if a closing safety sensor was installed and monitored (as provided for by the standard EN
16005) in order to activate the sensor test at the beginning of each cycle. Select OFF only if the safety
closing sensor has not been setup to be monitored.
For details, refer to the paragraph "Safety sensors".
Only if the function S06 was set to ON
Select ON if an opening safety sensor was installed and monitored (as provided for by the standard
EN 16005) in order to activate the sensor test at the beginning of each cycle. Select OFF only if the
opening safety sensor has not been setup to be monitored.
For details, refer to the paragraph "Safety sensors".
Only if the functions S07 and/or S08 are set to ON.
Selects the logic state of the test, used by the automation control unit to monitor the safety sensors.
The setup depends on the characteristics of the sensor installed.
Select OFF when using sensors of the type "OA-EDGE T" or "FLAT SCAN";
Contact configuration on OPEN input between terminals 0-3 of the control unit NEXT-L120S. Select
ON with a normally open contact or when the OPEN input is not used.
Select OFF when you use a device with a normally closed contact.
Choice of the work program selector.
OFF:
Manual selector or mechanical selector EV‑MSEL.
ON:
Digital selector ET-DSEL or T-NFC.
Select whether the door should only be closed by spring force (OFF), or if the motor (ON) must also be
enabled to provide greater reclosing force.
Function NOT used.
•
The automations are ready for the setup cycle.
Press the button (OK) to start the setup cycle.
5. SETUP CYCLE
•
The Master automation, after the 4 initial beeps, starts the opening cycle at low speed. At the end of the opening a 3" long beep signals
that the run of the Master automation has been saved. The Master leaf remains open.
•
The Slave automation, after the quick beeps before the start, starts the opening cycle at low speed. At the end of the opening a 3" long
beep signals that the run of the Slave automation has been saved.
•
The setup is over and the closing cycle occurs automatically, including at first the closing of the Slave leaf and after the closing leaf
delay, the new closing of the Master leaf.