Maintenance
Description
item No.
3JF
1-3-20
U611
G3 cable equalizer
Description
Sets the G3 cable equalizer.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Select the item to be set using the up/down cursor keys.
3. Press the start key.
The screen for the selected item appears.
Sets the G3 transmission cable equalizer.
Sets the G3 reception cable equalizer.
Display
REG. G3 TX EQR
REG. G3 RX EQR
Description
Setting the G3 transmission cable equalizer
Perform the following adjustment to make the equalizer compatible with the line characteristics.
1. Change the setting using the numeric keys.
0 km
1.8 km
3.6 km
7.2 km
Display
1: 0
2: 18
3: 36
4: 72
Description
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the G3 reception cable equalizer
Perform the following adjustment to make the equalizer compatible with the line characteristics.
1. Change the setting using the numeric keys.
0 km
1.8 km
3.6 km
7.2 km
Display
1: 0
2: 18
3: 36
4: 72
Description
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No. is
displayed.