3JF
1-3-4
(2) Contents of maintenance mode items
Maintenance
Description
item No.
U600
Initializing all data
Description
Initializes software switches and all data in the backup data on the fax control PCB, according to the destination
and OEM.
Executes the check of the file system, when abnormality of the file system is detected, initializes the file system,
communication past record and register setting contents.
Purpose
To initialize the fax control PCB.
Method
1. Press the start key. The screen for entering the destination code is displayed.
Enter a destination code using the numeric keys (refer to the destination code list on page 1-3-5 for the
destination code).
INI. ALL DATA
COUNTRY CODE:000
2. Press the start key. The screen for entering the OEM code is displayed.
There is no operation necessary on this screen.
INI. ALL DATA
OEM CODE:000
3. Press the start key. Data initialization starts. To cancel data initialization, press the stop/clear key.
4. After data initialization, the entered destination and OEM codes are displayed, and the ROM version is
displayed two seconds later.
INI. ALL DATA
COMPLETED 000 000
INI. ALL DATA
COMPLETED V1.00
Caution
If initialized with “000” (code for Japan) entered as the destination code, service call code C0820 (fax control
PCB problem) will be detected. Be sure to enter the correct destination code. If C0820 (fax control PCB
problem) is detected, press the COPY key to put the machine in the copy mode and then execute this
maintenance item again to enter the correct destination code and initialize data.