Maintenance
Description
item No.
3JF
1-3-16
Setting the frequency of the CED signal
Sets the frequency of the CED signal. Used as one of the measures to improve transmission performance for
international communications.
1. Enter 1 or 2 using the numeric keys to change the frequency.
2100 Hz
1100 Hz
Display
1: 2100
2: 1100
Frequency of the CED signal
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No. is
displayed.
U609
Setting communication time
Description
Sets the time-out time for fax transmission.
Purpose
Used mainly to improve transmission performance for international communications.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Select the item to be set using the up/down cursor keys.
3. Press the start key.
The screen for the selected item appears.
Sets the T0 time-out time.
Sets the T1 time-out time.
Sets the T2 time-out time.
Sets the Ta time-out time.
Sets the Tb1 time-out time.
Sets the Tb2 time-out time.
Sets the Tc time-out time.
Sets the Td time-out time.
Display
T0
T1
T2
Ta
Tb1
Tb2
Tc
Td
Description
Setting the T0 time-out time
Sets the time before detecting a CED or DIS signal after a dialing signal is sent. Depending on the quality of the
exchange, or when the auto select function is selected at the destination unit, a line can be disconnected.
Change the setting to prevent this problem.
1. Change the setting using the numeric keys.
30 to 90 s
Description
T0 time-out time
Setting range
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the T1 time-out time
Sets the time before receiving the correct signal after call reception. No change is necessary for this
maintenance item.
1. Change the setting using the numeric keys.
30 to 90 s
Description
T1 time-out time
Setting range
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
U608
(cont.)