Maintenance
Description
item No.
3JF
1-3-12
U607
Setting the system (communication 1)
Description
Makes settings for fax transmission regarding the communication.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Select the item to be set using the up/down cursor keys.
3. Press the start key.
The screen for the selected item appears.
Sets the auto redialing interval.
Sets the number of times of auto redialing.
Sets the communication starting speed.
Sets the reception speed.
Sets the mode for remote switching.
Sets the transmission intervals.
Sets the loop current detection before dialing.
Sets the DIS signal to 4 bytes.
Display
INTERVAL
TIMES
TX SPEED
RX SPEED
REMOTE
CALL INT
DC LOOP
DIS 4BYTE
Description
Setting the auto redialing interval
Change the setting to prevent the following problems: fax transmission is not possible due to too short redial
interval, or fax transmission takes too much time to complete due to too long redial interval.
1. Change the setting using the numeric keys.
1 to 9 (min.)
Description
Redialing interval
Setting range
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the number of times of auto redialing
1. Change the setting using the numeric keys.
0 to 9
Description
Number of redialing
Setting range
When set to 0, no redialing is performed.
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the communication starting speed
Sets the initial communication speed when starting transmission. When the destination unit has V.34 capability,
V.34 is selected for transmission, regardless of this setting.
1. Change the setting using the numeric keys.
V.17, 14400 bps
V.17, 9600 bps
V.27ter, 4800 bps
V.27ter, 2400 bps
Display
1: 144
2: 96
3: 48
4: 24
Description
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the reception speed
Sets the reception speed that the sender is informed of using the DIS or NSF signal. When the destination unit
has V.34 capability, V.34 is selected, regardless of the setting.
1. Change the setting using the numeric keys.
V.17, V.33, V.29, V.27ter
V.29, V.27ter
V.27ter
V.27ter (fallback only)
Display
1: 144
2: 96
3: 48
4: 24
Description
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.