3-51
Enhancement device setup procedure > Optional device installation
[CONFIDENTIAL]
31
Attach the PF connecting plate [A] on the right side of AK-9110 (Screw x2: M5x10).
Preparation for PF-9100
32
Remove all visible external tapes on the external surfaces of the paper feeder.
33
Pull the cassette 5, 6 and then remove the shipping materials [A] [B].
34
Lift the rear right cover [A] of the paper feeder slightly and remove it (screw x6).
These parts are used in Step 45, or used in Step 86 when connect to 2nd PF-9100.
[A]
[A]
[A]
[B]