6-13
Machine transportation after setup > Procedure for the main unit transportation (floor to floor)
[CONFIDENTIAL]
24
If it gets less clogged nozzle, repeat step 22 to 23 with following order.
1
Run the strong purge. (cleaning) only for the color that has non-discharge area.
2
Run the extra strong purge. (cleaning) only for the color that has non-discharge area.
3
Run the extra strong purge. (cleaning) only for the color that has non-discharge area.
4
Run the extra strong purge. (cleaning) only for the color that has non-discharge area.
25
Select [Adjust] and the chart is output automatically.
26
Place the test chart (with correction) on the scan table and scan it.
27
Select [STOP] and exit from this mode.