1-1
Environment >
[CONFIDENTIAL]
1 Environment
Installation environment
Installation location
The environmental conditions are as follows:
It is recommended that the machine operates in room temperature of, 64.4 to 80.6°F/18to 27°C, and humidity between
30 to 80% for optimum performance.
Operations outside this range may affect the image quality or may not be printed.
Avoid the following locations.
•
Locations of direct sunlight, such as by a window.
•
Locations with floor vibrations
•
Locations with rapid temperature fluctuations
•
Locations where hot or cold air is blown directly.
•
Locations with poor ventilation.
Due to the weight of the main unit, certain floor material can become damaged by moving this product after setup.
If the machine is run over a long period of time in a poor ventilation environment, such as a small enclosed room, the
operation may emit an unpleasant smell. Proper ventilation of the room is important when considering setup location.
1.
Temperature: 59 to 86°F/15 to 30°C (Humidity should be 54% or less in 86°F/30°C)
2.
Humidity: 15 to 80% RH (Temperature should be 80.6°F/27°C or less in 80% RH.)
3.
Product name
Rated voltage
Rated current
Power requirements
Main unit
AC120V 60Hz
8.5A or more
AC 220 to 240V 50Hz
5.0A or more
AK-9110
(Supplied from Main unit)
-
AK-9120
AC 120V 60Hz
-
AK-9130
(Supplied from PF-9100)
-
DE-9100
AC 120V 60Hz
10.7A+11.2A or more
AC 220 to 240V 50Hz
4.9A+5.0A or more
DF-9100
(Supplied from DE-9100)
-
Print System 50
AC 120V 60Hz
3.0A or more
AC 220 to 240V 50Hz
1.6A or more
PF-9100
AC 120V 60Hz
7.2A or more
AC 220 to 240V 50Hz
4.0A or more
ST-9100
AC 120V 60Hz
1.1A or more
AC 220 to 240V 50Hz
0.7A or more
4.
Frequency fluctuation: 50Hz +/- 2% or 60Hz +/- 2%
IMPORTANT
Refrain from moving the main unit after setup.
Follow
"Machine transport after setup"
if necessary.