Troubleshooting Basics
KVAL Operation/Service Manual
5-6
• Does the
Position Feed Back
agree with the
Load
position?
In other words are the correct photo eyes, limit switches or ferrous sensors acti-
vated?
Check the controller inputs to insure the proper sensors are activated. If the control-
ler is a PLC, an activated input is lit. Some touch screens have inputs status also.
3.
Common Position Feedback failures:
• Photo Eye:
a)
Bad element or bad cable
b) Eyes not set to correct height
c) Lighting from ceiling may be interfering with sensor
•
Limit Switch:
Stuck, or failure
•
Wiring:
Broken, worn insulation
•
PLC:
Bad input port
• Bad Output:
Relay may be stuck
• Air Solenoid Valve:
May be stuck or not working.
4.
Check the Positioning System
Follow the circuit from the
Controller
output to the
Load
and check for compo-
nent failures.