About a Typical Pneumatic Circuit
5-15
KVAL Operation/Service Manual
4.
The
PLC
senses the voltage from the
Extend Sensor
and removes the control voltage
to the
Control Valve.
Retract Process
If the
PLC
determines the conditions are right to retract the
Router
:
1.
The
Control Valve
directs compressed air to the retract port of the
Cylinder.
2.
The
Cylinder
and
Router
retract deactivating the
Extend Sensor
3.
When the
Cylinder
and
Router
are fully retracted, the
Retract Sensor
is activated.
4.
The
PLC
senses the voltage from the
Retract Sensor
completing the process
Positioning
System
Load
Force
Translated
Positioning
PLC
Instructions
Position Feedback
Extend Sensor:
Retracted Sensor:
Deactivated
Activated
24 Volts
Extended
Cylinder
24 V Applied
Router Assembly (Load)
Position Feed Back
Air In
Control Valve
Extend
Sensor
Activated
Air Pressure Extends
Cylinder and Router
Assembly
EXTENDED
Summary of Contents for 990FX
Page 4: ...KVAL 990 FX Operation Service Manual ...
Page 30: ...Safety Sign Off Sheet KVAL 990 FX Operation Service Manual 1 20 ...
Page 85: ...Glossary of Common Terms 2 55 KVAL Operation Service Manual ...
Page 90: ...System IT Administration 3 5 KVAL Operation Service Manual ...
Page 129: ...Collet Torque Values 4 39 KVAL 990 FX Operation Service Manual ...
Page 130: ...Collet Torque Values KVAL 990 FX Operation Service Manual 4 40 ...
Page 164: ...Network System Overview KVAL Operation Service Manual 5 34 ...
Page 168: ...KVAL 990 FX Operation Service Manual ...
Page 169: ......
Page 170: ......
Page 171: ......