![Kval 990FX Operation And Service Manual Download Page 154](http://html.mh-extra.com/html/kval/990fx/990fx_operation-and-service-manual_2012811154.webp)
Troubleshooting Electrical Problems
KVAL Operation/Service Manual
5-24
1.
Check Motor Overload Circuits
2.
With power on, check the trip indicator LED on the
overload. If indicator is orange, press the Reset
Button to reset the overload circuit. Retest the
Machine.
Overload Relay Light OFF
Contactors
Overload
Relays
Reset Button. Fac-
tory set on the ''H''
Setting.
Test or Stop
Trip Indicator
Factory Set Current
Rating Adjust
E-Stop Light OFF
Check to see the if any E-Stop buttons are pulled out.
NOTE:
Location and quantity of E-Stop buttons varies
depending on customer need. Typical locations for E-
Stop buttons are near the Rear Access Gate and near
the Tool Changer Access Gate
Stop Light OFF
Check for 110 VAC between #2 and #4 If there is
voltage, press the Start button. If no voltage, check
the Stop button to make sure it is all the way out and
not stuck in, then check the contact to make sure it is
closed. If still no voltage, check the wiring.
Summary of Contents for 990FX
Page 4: ...KVAL 990 FX Operation Service Manual ...
Page 30: ...Safety Sign Off Sheet KVAL 990 FX Operation Service Manual 1 20 ...
Page 85: ...Glossary of Common Terms 2 55 KVAL Operation Service Manual ...
Page 90: ...System IT Administration 3 5 KVAL Operation Service Manual ...
Page 129: ...Collet Torque Values 4 39 KVAL 990 FX Operation Service Manual ...
Page 130: ...Collet Torque Values KVAL 990 FX Operation Service Manual 4 40 ...
Page 164: ...Network System Overview KVAL Operation Service Manual 5 34 ...
Page 168: ...KVAL 990 FX Operation Service Manual ...
Page 169: ......
Page 170: ......
Page 171: ......