About a Typical Pneumatic Circuit
KVAL Operation/Service Manual
5-12
About a Typical Pneumatic Circuit
A control valve (solenoid) is used to drive cylinders to move different loads in the machine. The
solenoid if controlled by the PLC by applying a high voltage or a low voltage to a control coil.
Controls for example are: extending and retracting router, drill, clamping a door.
FIGURE 5- 21.
Block Diagram of a Pneumatic Circuit
PLC
Output
High
Pressure
Air
Cylinder
Common
Control Circuit
ON
Measure
24 VDC here
Control Voltage
Should have High
Pressure air here
Cylinder
Control
Control
(Coil)
Input
Air
Input
Air
Output
Valve
Should have High
Pressure air on
Activated Output
Schematic Drawing of Pneumatic Circuit
Note:
Pre-2006
machines may
not contain the
24 Volt relay.
120 Vac is
directly fed into
the Control Coil.
Check the input
circuitry to the
Control Coil for
120 Vac.
Note:
In this
sample set-up,
Port A is nor-
mally open and
Port B is nor-
mally closed. If
power is OFF,
air should be on
Port B.
Summary of Contents for 990FX
Page 4: ...KVAL 990 FX Operation Service Manual ...
Page 30: ...Safety Sign Off Sheet KVAL 990 FX Operation Service Manual 1 20 ...
Page 85: ...Glossary of Common Terms 2 55 KVAL Operation Service Manual ...
Page 90: ...System IT Administration 3 5 KVAL Operation Service Manual ...
Page 129: ...Collet Torque Values 4 39 KVAL 990 FX Operation Service Manual ...
Page 130: ...Collet Torque Values KVAL 990 FX Operation Service Manual 4 40 ...
Page 164: ...Network System Overview KVAL Operation Service Manual 5 34 ...
Page 168: ...KVAL 990 FX Operation Service Manual ...
Page 169: ......
Page 170: ......
Page 171: ......