Description of the Six Light Panel
2-29
KVAL Operation/Service Manual
Description of the Six Light Panel
The six lights on this panel indicate the status of the power-up of the system. Each machine has
this panel.
The Sequence that the lights activate is as follows:
Sequence
Order
Light Designation
Description
1
Control Power
This light illuminates when the Control Transformer turned on
and the power is working on secondary side-of transformer
2
Overload Relay
Checks the Overload Relay in the E-Box. In some cases, this
circuit is jumped. In these cases it should always light when
the Control Power turns on.
3
E-Stop
All gates are closed and the E-stops are not activated when
this light is on.
4
Stop
This light will be on if Machine Stop button is deactivated.
5
Start
This light will be on once the Machine Start button is pressed
and the ACR Relay is latched.
6
24VDC
This light comes on once the ACR is latch and the 24VDC
power Supply is working
Control Power
First
Overload Relay
Second
E-Stop
Third
24VDC –
Sixth
Stop –
Fourth
Start –
Fifth
Summary of Contents for 990FX
Page 4: ...KVAL 990 FX Operation Service Manual ...
Page 30: ...Safety Sign Off Sheet KVAL 990 FX Operation Service Manual 1 20 ...
Page 85: ...Glossary of Common Terms 2 55 KVAL Operation Service Manual ...
Page 90: ...System IT Administration 3 5 KVAL Operation Service Manual ...
Page 129: ...Collet Torque Values 4 39 KVAL 990 FX Operation Service Manual ...
Page 130: ...Collet Torque Values KVAL 990 FX Operation Service Manual 4 40 ...
Page 164: ...Network System Overview KVAL Operation Service Manual 5 34 ...
Page 168: ...KVAL 990 FX Operation Service Manual ...
Page 169: ......
Page 170: ......
Page 171: ......