Initial Powering Operations for the 990-FX Line
2-35
KVAL Operation/Service Manual
How to Power Down the Machine
1.
Push the
Stop
button for each machine, located on the
Operator’s Station
2.
Shut down the operating system, by selecting
Shutdown
from the Desktop.
Note:
Make sure Windows is shutdown completely before
turning off the machine. Hard drive or data may be
damaged if not turned off in this order.
3.
Switch the green
CONTROL TRANSFORMER
switches for
each machine to the OFF position.
4.
KVAL also recommends that you turn the disconnect
switches on the electrical cabinets to OFF; this helps reduce
possible damage resulting from power surges from electri-
cal storms.
Emergency Shutdown and Recovery
There are emergency shutdown (E-Stop) switch located at key points
around the machine.
The E-Stop switches are to be used when the machine is out of control
or is about to damage personnel or equipment.
When an E-Stop switch is activated, power to the machine is killed.
The machine responds, in the same way, if you press the STOP button
on the operator's station.
To Resume Normal Operation after an E-Stop
If an E-Stop is activated, use the following procedure to recover, after the cause of the emergency
stop is resolved:
1.
De-activate the E-Stop switch by pulling it out.
2.
Push the
START MACHINE
button on the operator's station
3.
Home the Machine.
1
2
3
Summary of Contents for 990FX
Page 4: ...KVAL 990 FX Operation Service Manual ...
Page 30: ...Safety Sign Off Sheet KVAL 990 FX Operation Service Manual 1 20 ...
Page 85: ...Glossary of Common Terms 2 55 KVAL Operation Service Manual ...
Page 90: ...System IT Administration 3 5 KVAL Operation Service Manual ...
Page 129: ...Collet Torque Values 4 39 KVAL 990 FX Operation Service Manual ...
Page 130: ...Collet Torque Values KVAL 990 FX Operation Service Manual 4 40 ...
Page 164: ...Network System Overview KVAL Operation Service Manual 5 34 ...
Page 168: ...KVAL 990 FX Operation Service Manual ...
Page 169: ......
Page 170: ......
Page 171: ......