![Kval 965X Operation Manual Download Page 84](http://html.mh-extra.com/html/kval/965x/965x_operation-manual_2012796084.webp)
Routers: How to Isolate and Calibrate a Specific Router
3-18
965X Operation Manual
Routers: How to Isolate and Calibrate a Specific Router
Sometimes to obtain a good calibration, it may be necessary to isolate and verify a specific router.
1.
Use the
Tool Config
page to disable all tools except the router to be verified.
2.
Create a
Door Job
that has a rectangle with
Width
= 1.5 * (Nominal Tool Diameter).
•
For Example:
If it is a 1.0 inch diameter router then set the Width = 1.5 * 1.0 =1.5
3.
Set the
Length
large enough for the tool to fit in the Cut
•
For Example:
If it is a 1.0 inch diameter router then set the Width = 2.0*1.0 = 1.0
4.
Set the depth deep enough to measure.
•
For Example:
0.15 inches).
FIGURE 3- 12.
Feature Details and Tool Configuration
Summary of Contents for 965X