Kurz
B
‐
Series
Operations
Guide
2–
25
B
‐
Series
Flow
Meter
Display Mode Options
Option 42 — Flow Data
To
view
the
Flow
Data
menu
in
Display
mode:
1>
Press
D
.
2>
Press
2
to
invoke
the
Quick
Jump
option.
3>
Press
42
for
the
Flow
Data
menu,
and
then
press
E
.
TAG PRIMARY AIR
RT 2102.48 HRS
The
prompt
showing
the
meter
name
and
total
runtime
appears.
4>
Press
P
to
continue.
FLOW RATE
2.685377 SCFM
The
prompt
for
the
current
flow
rate
appears.
5>
Press
P
to
continue.
MSCF = 11.93814
ET 130260.8 MIN
The
prompt
showing
the
accumulated
totalized
flow
since
the
last
time
the
totalized
flow
was
reset
appears.
The
“M”
designation
reflects
millions
(10
6
).
6>
Press
P
to
continue.
VELOCITY
2.392474 SFPM
The
prompt
showing
the
current
velocity
appears.
7>
Press
P
to
continue.
REF. DENSITY
0.073939 LB/CF
The
Reference
Density
prompt
reflects
the
density
of
the
process
gas
that
the
meter
is
calibrated
to
measure.
Summary of Contents for 410FTB
Page 1: ...Operations Guide for B Series Flow Meters 368042E...
Page 4: ...Kurz B Series Operations Guide iv...
Page 9: ...Kurz B Series Operations Guide ix Preface...
Page 33: ...Kurz B Series Operations Guide 1 20 B Series Flow Meter Modes Menus...
Page 65: ...Kurz B Series Operations Guide 2 32 B Series Flow Meter Display Mode Options...
Page 141: ...Kurz B Series Operations Guide 4 68 Program Mode Advanced Setup...