Kurz
B
‐
Series
Operations
Guide
4–12
Program Mode
Advanced Setup
Option 5 — Setting Up Analog Output 1
The
output
and
signal
range
for
process
variables
measured
by
the
flow
meter
are
configured
through
the
Analog
Output
Setup
menu
in
Program
mode.
The
receiving
device
must
be
programmed
for
the
same
range.
The
flow
meter
supports
up
to
two
analog
output
(AO)
channels.
Each
analog
output
channel
(AO1
and
AO2)
can
report
flow
rate,
temperature,
velocity,
or
be
assigned
to
a
PID
flow
controller.
Both
channels
are
active
during
the
zero
‐
mid
‐
span
drift
check.
The
drift
check
and
NE
‐
43
alarms
are
temporary
overrides
to
the
analog
output
signals.
To
access
the
Analog
Output
Setup
menu
in
Program
mode:
1>
Press
P
.
2>
Enter
the
Advanced
access
code,
and
then
press
E
.
3>
Press
2
to
invoke
the
Quick
Jump
option.
4>
Press
5
for
the
Analog
Out
1
menu
and
then
press
E
.
The
following
example
uses
the
Analog
Out
1
option
with
the
flow
rate
feature.
ANALOG OUT 1 >
FLOW RATE ^v
5>
Use
the
arrow keys
to
scroll
through
the
list,
then
press
E
.
AO1 at 4mA
>0.00000000 SCFM
Table 4
‐
1.
4
‐
20
mA
Output
Functions
Analog
Output
Functions
Description
Flow
rate
Process
measurement.
Temperature
Velocity
PID
flow
controller
Control
valve
position,
damper
position,
or
motor
controller
speed.
Table 4
‐
2.
Temporary
4
‐
20
mA
Process
Measurement
Override
Drift
Check
NE
‐
43
Alarms
Trigger
Internal
timer
Flow
meter
error
conditions.
Trigger
DI2
input
Summary of Contents for 410FTB
Page 1: ...Operations Guide for B Series Flow Meters 368042E...
Page 4: ...Kurz B Series Operations Guide iv...