Operations
Guide
4–10
Program Mode
Advanced Setup
Option 4 — Flow Totalizer Reset
Flow
applications
frequently
must
totalize
the
flow
to
know
the
accumulated
volume
or
mass
going
through
the
pipe
or
duct.
The
flow
meter
measures
several
process
variables
including
the
accumulation
of
the
total
flow
in
volume
or
mass.
•
Volume
uses
standard
cubic
feet
(SCF)
or
standard
cubic
meters
(SCM)
•
Mass
uses
pounds
(lb)
or
kilograms
(kg)
You
can
manually
reset
the
flow
totalizer
value
to
zero
or
configure
it
to
reset
when
it
reaches
a
specified
value.
To
access
the
Flow
Totalizer
Reset
menu
in
Program
mode:
1>
Press
P
.
2>
Enter
the
Advanced
access
code,
and
then
press
E
.
3>
Press
2
to
invoke
the
Quick
Jump
option.
4>
Press
4
for
the
Flow
Totalizer
Reset
Setup
menu,
and
then
press
E
.
The
menu
prompts
you
for
a
manual
or
automatic
reset.
5>
Use
the
arrow
keys
to
select
either
MANUAL
RESET
or
AUTOMATIC
RESET
,
and
then
press
E
.
Manual
Reset
TOTALIZER RESET
>MAN RESET ^v
You
will
be
prompted
to
confirm
resetting
the
totalizer.
RESET FLOW TOTAL
>YES ^v
6>
Use
the
arrow
keys
to
select
YES
and
then
press
E
.
7>
Press
P
to
exit
the
prompt
without
changes.
The
following
information
appears.
RESETING FLOW
TOALIZER . . .
TOTALIZER IS
RESET . . .
Summary of Contents for 410FTB
Page 1: ...Operations Guide for B Series Flow Meters 368042E...
Page 4: ...Kurz B Series Operations Guide iv...
Page 9: ...Kurz B Series Operations Guide ix Preface...
Page 33: ...Kurz B Series Operations Guide 1 20 B Series Flow Meter Modes Menus...
Page 65: ...Kurz B Series Operations Guide 2 32 B Series Flow Meter Display Mode Options...
Page 141: ...Kurz B Series Operations Guide 4 68 Program Mode Advanced Setup...