Kurz
B
‐
Series
Operations
Guide
4–6
Program Mode
Advanced Setup
ANALOG OUT
>FLOW RATE
^
v
The
Analog
Output
options
include
flow
rate,
velocity,
temperature,
and
PID.
The
availability
of
options
is
based
on
other
settings.
12>
Use
the
arrow
keys
to
select
an
Analog
Output
option,
and
then
press
E
.
AO1 at 4mA
>0.0000000 SCFM
The
analog
output
4 mA
prompt
determines
the
minimum
range
value;
that
is,
the
low
process
flow
value
equivalent
to
4 mA.
The
flow
unit
was
specified
in
a
previous
option.
13>
Use
the
number
and
decimal
keys
to
enter
the
4 mA
value.
Press
E
.
AO1 at 20mA
>15000.000 SCFM
The
analog
output
20 mA
prompt
determines
the
maximum
range
value;
that
is,
the
high
process
flow
value
equivalent
to
20 mA.
The
flow
unit
was
specified
in
a
previous
option.
14>
Use
the
number
and
decimal
keys
to
enter
the
20 mA
value.
Press
E
.
Note:
If
the
flow
meter
was
configured
with
a
second
analog
output,
prompts
will
appear
for
AO2
at
4 mA
and
AO2
at
20 mA.
RUN MODE DISPLAY
>STATIC
^
v
The
Run
Mode
options
are
static
variables
and
scrolled
variables.
Refer
to
Chapter
1
for
a
description
of
static
and
scrolled
modes.
15>
Use
the
arrow keys
to
select
the
Run
Mode
Display,
and
then
press
E
.
Depending
on
the
run
mode
selection,
the
static
variable
or
scrolled
variables
prompt
appears.
STATIC VARS
>FLOW+TEMP
^
v
SCROLLED VARS
>SCROLL ALL
^
v
Summary of Contents for 410FTB
Page 1: ...Operations Guide for B Series Flow Meters 368042E...
Page 4: ...Kurz B Series Operations Guide iv...