Kurz
B
‐
Series
Operations
Guide
4–21
Program Mode
Advanced Setup
Option 9 — Setting Up Alarms
The
flow
meter
can
be
manufactured
to
support
up
to
two
alarms.
The
alarms
can
be
monitored
on
the
display,
via
ASCII
or
Modbus
commands,
or
through
the
HART
interface.
Additionally,
the
alarms
can
be
setup
to
send
a
control
signal
(energize
a
relay
output)
when
an
alarm
event
occurs.
Note
It
is
recommended
that
you
start
with
the
Option
8,
Relay
Output
Setup
,
to
avoid
assigning
conflicting
relays.
See
on
for
information.
Note
As
the
relays
are
optically
isolated
solid
‐
state
relays
(SPST
switching),
their
non
‐
powered
state
is
an
open
circuit
and
must
be
considered
for
fail
‐
safe
alarm
logic
configurations.
Note
The
alarm
relays
are
rated
for
0.5A.
To
access
the
Alarm
Setup
menu
in
Program
mode:
1>
Press
P
.
2>
Enter
the
Advanced
access
code,
and
then
press
E
.
3>
Press
2
to
invoke
the
Quick
Jump
option.
4>
Press
9
for
the
Alarm
Setup
menu,
and
then
press
E
.
The
following
information
appears
if
the
meter
was
not
purchased
with
the
alarm
option:
ALARM FUNCTION
IS NOT INSTALLED
If
you
would
like
the
Alarm
function
available,
contact
the
Kurz
representative.
If
the
meter
is
configured
with
the
alarm
option,
you
are
prompted
for
an
alarm
number.
SET ALARM #
>1
5>
Use the
numeric
keys
to
enter
either
1
or
2
for
the
alarm
number,
and
then
press
E
.
SET ALARM 1
>ON
You
are
prompted
to
turn
the
alarm
ON
or
OFF.
Summary of Contents for 410FTB
Page 1: ...Operations Guide for B Series Flow Meters 368042E...
Page 4: ...Kurz B Series Operations Guide iv...
Page 9: ...Kurz B Series Operations Guide ix Preface...
Page 33: ...Kurz B Series Operations Guide 1 20 B Series Flow Meter Modes Menus...
Page 65: ...Kurz B Series Operations Guide 2 32 B Series Flow Meter Display Mode Options...
Page 141: ...Kurz B Series Operations Guide 4 68 Program Mode Advanced Setup...