gemino
55
PROGRAMMING MENU
CERTIFICATIONS
MANAGEMENT MENU
CLEANING THE KEYPAD
DEFAULT DATA RESTORAL
Scrolling the programming menu is possible to modify the settings described
previously. Below is shown the programming menu order. Refer to the Multifunction
LCD Keypad
ergo
quick reference guide for the character insertion function,
menu scrolling, deleting operations, etc.
Phonebook → Network option → Line option → Decoder C-ID → gemino options
→ Outputs → Events → Change PIN → Installer data → Version
Scrolling the management menu is possible to check the status of the device and
to programm the address book. Below is shown the management menu order.
Phonebook → Gemino status → Change PIN → Backlight
IMPORTANT
Do not use aggressive chemical products or acids.
To clean the keypad press the ESC key for three seconds. For the following 30
seconds the keys will remain inactive avoiding accidental activation.
gemino
can be re-setted to the default programming data in few seconds,
performing the follow steps:
1. Turn off the device
2. insert a jumper between terminals
O2
and
A
(
gemino
) or between the terminals
O2
and
i1
(
gemino4
)
3. Power up the device
4. After few seconds only the signalisation LED1 stays lit
5. Turn off the device and remove the jumper.